Acessibilidade / Reportar erro

Assessing ultrasonographic optic nerve sheath diameter in animal model with anesthesia regimens

ABSTRACT

Purpose:

To determine the normal optical nerve sheath (ONS) diameter ultrasonography (ONSUS) and evaluate the possible effects of drugs on ONS diameter during anesthetic induction in healthy pigs.

Methods:

Healthy piglets were divided into three groups: a control group, that received xylazine and ketamine (X/K); other that received xylazine, ketamine and propofol (X/K/P); and a third group that received xylazine, ketamine, and thiopental (X/K/T). The sheath diameter was assessed by ultrasonography calculating the average of three measurements of each eye from the left and right sides.

Results:

118 animals were anesthetized (49 X/K 33 X/K/P and 39 X/K/T). Mean ONS sizes on both sides in each group were 0.394 ± 0.048 (X/K), 0.407 ± 0.029 (X/K/P) and 0.378 ± 0.042 cm (X/K/T) (medians of 0.400, 0.405 and 0.389, respectively). The ONS diameter varied from 0.287–0.512 cm (mean of 0.302 ± 0.039 cm). For group X/K, the mean diameter was 0.394 ± 0.048 cm. Significant differences in ONS sizes between the groups P and T (X/K/P > X/K/T, p = 0.003) were found. No statistically significant differences were detected when other groups were compared (X/K = X/K/P, p = 0.302; X/K = X/K/T, p = 0.294).

Conclusions:

Sedation with thiopental lead to significative ONS diameter reduction in comparison with propofol. ONSUS may be useful to evaluate responses to thiopental administration.

Key words
Intracranial Pressure; Intracranial Hypertension; Experimental Research

Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia https://actacirbras.com.br/ - São Paulo - SP - Brazil
E-mail: actacirbras@gmail.com