Accessibility / Report Error
Sort publications by
Radiologia Brasileira, Volume: 57, Published: 2024
  • Performance of ChatGPT on questions from the Brazilian College of Radiology annual resident evaluation test Original Article

    Leitão, Cleverson Alex; Salvador, Gabriel Lucca de Oliveira; Rabelo, Leda Maria; Escuissato, Dante Luiz

    Abstract in Portuguese:

    Resumo Objetivo: Testar o desempenho do ChatGPT em questões de radiologia formuladas pelo Colégio Brasileiro de Radiologia (CBR), avaliando seus erros e acertos. Materiais e Métodos: 165 questões da avaliação anual dos residentes do CBR (2018, 2019 e 2022) foram apresentadas ao ChatGPT. Elas foram divididas, para análise estatística, em questões que avaliavam habilidades cognitivas de ordem superior ou inferior e de acordo com a subespecialidade, o tipo da questão (descrição de um achado clínico ou sinal, manejo clínico de um doente, aplicação de um conceito, cálculo ou classificação dos achados descritos, associação entre doenças ou anatomia) e o ano da residência (R1, R2 ou R3). Resultados: O ChatGPT acertou 53,3% das questões (88/165). Houve diferença estatística entre o desempenho em questões de ordem cognitiva inferior (64,4%; 38/59) e superior (47,2%; 50/106) (p = 0,01). Houve maior índice de acertos em física (90,0%; 18/20) do que em questões clínicas (48,3%; 70/145) (p = 0,02). Não houve diferença significativa de desempenho entre subespecialidades ou ano de residência (p > 0,05). Conclusão: Mesmo sem treinamento dedicado a essa área, o ChatGPT apresenta desempenho razoável, mas ainda insuficiente para aprovação, em questões de radiologia formuladas pelo CBR.

    Abstract in English:

    Abstract Objective: To test the performance of ChatGPT on radiology questions formulated by the Colégio Brasileiro de Radiologia (CBR, Brazilian College of Radiology), evaluating its failures and successes. Materials and Methods: 165 questions from the CBR annual resident assessment (2018, 2019, and 2022) were presented to ChatGPT. For statistical analysis, the questions were divided by the type of cognitive skills assessed (lower or higher order), by topic (physics or clinical), by subspecialty, by style (description of a clinical finding or sign, clinical management of a case, application of a concept, calculation/classification of findings, correlations between diseases, or anatomy), and by target academic year (all, second/third year, or third year only). Results: ChatGPT answered 88 (53.3%) of the questions correctly. It performed significantly better on the questions assessing lower-order cognitive skills than on those assessing higher-order cognitive skills, providing the correct answer on 38 (64.4%) of 59 questions and on only 50 (47.2%) of 106 questions, respectively (p = 0.01). The accuracy rate was significantly higher for physics questions than for clinical questions, correct answers being provided for 18 (90.0%) of 20 physics questions and for 70 (48.3%) of 145 clinical questions (p = 0.02). There was no significant difference in performance among the subspecialties or among the academic years (p > 0.05). Conclusion: Even without dedicated training in this field, ChatGPT demonstrates reasonable performance, albeit still insufficient for approval, on radiology questions formulated by the CBR.
  • Analysis of the indications for and results of breast cancer screening by magnetic resonance imaging at a cancer center in Brazil Original Article

    Zoghbi, Karina Kuhl; Felipe, Vinicius Cardona; Graziano, Luciana; Guatelli, Camila Souza; Souza, Juliana Alves de; Bitencourt, Almir Galvão Vieira

    Abstract in Portuguese:

    Resumo Objetivo: Avaliar as indicações e resultados de exames de ressonância magnética (RM) para rastreamento de câncer de mama em um centro oncológico no Brasil. Materiais e Métodos: Estudo observacional, realizado mediante análise retrospectiva de pacientes submetidos a RM das mamas para rastreamento de câncer de mama, por meio de revisão do prontuário eletrônico em um centro oncológico. Resultados: Foram incluídas 597 pacientes com idade variando de 19 a 82 anos. As principais indicações para rastreamento foram história pessoal de câncer de mama em 354 (59,3%) pacientes, história familiar em 102 (17,1%) e mutação genética confirmada em 67 (11,2%). O resultado da RM foi benigno (BI-RADS 1 ou 2) em 425 (71,2%) pacientes, provavelmente benigno (BI-RADS 3) em 143 (24,0%) e suspeito (BI-RADS 4 ou 5) em 29 (4,9%). Foram identificados 11 tumores malignos na RM, todos carcinomas invasivos, porcentagem de cânceres “mínimos” (< 1 cm) de 54,5% e porcentagem de axila negativa de 90,9%. A taxa de detecção de câncer na RM foi 18,4/1000 exames e o valor preditivo positivo para as lesões suspeitas submetidas a biópsia foi 37,9%. Conclusão: A principal indicação para RM de rastreamento na nossa população foi história pessoal de câncer de mama. Os resultados mostraram que a RM constitui um método com alta acurácia para detecção precoce de neoplasias da mama nessa população.

    Abstract in English:

    Abstract Objective: To evaluate the indications for and results of magnetic resonance imaging (MRI) examinations for breast cancer screening at a cancer center in Brazil. Materials and Methods: This was a retrospective observational study, based on electronic medical records, of patients undergoing MRI for breast cancer screening at a cancer center in Brazil. Results: We included 597 patients between 19 and 82 years of age. The main indications for MRI screening were a personal history of breast cancer, in 354 patients (59.3%), a family history of breast cancer, in 102 (17.1%), and a confirmed genetic mutation, in 67 (11.2%). The MRI result was classified, in accordance with the categories defined in the Breast Imaging Reporting and Data System, as benign (category 1 or 2), in 425 patients (71.2%), probably benign (category 3), in 143 (24.0%), or suspicious (category 4 or 5), in 29 (4.9%). On MRI, 11 malignant tumors were identified, all of which were invasive carcinomas. Among those 11 carcinomas, six (54.5%) were categorized as minimal cancers (< 1 cm), and the axillary lymph nodes were negative in 10 (90.9%). The cancer detection rate was 18.4/1,000 examinations, and the positive predictive value for suspicious lesions submitted to biopsy was 37.9%. Conclusion: In our sample, the main indication for breast MRI screening was a personal history of breast cancer. The results indicate that MRI is a highly accurate method for the early detection of breast neoplasms in this population.
  • “Interstitial lung abnormalities”: translation to and use in Portuguese Original Article

    Yamanari, Tassia Regina; Auad, Ricardo Valarelli; Mançano, Alexandre Dias; Koenigkam-Santos, Marcel; Santana, Pablo Rydz Pinheiro; Souza Júnior, Arthur Soares; Chate, Rodrigo Caruso; Sawamura, Marcio Valente Yamada

    Abstract in Portuguese:

    Resumo Objetivo: Fazer um levantamento sobre o uso do termo interstitial lung abnormalities nos laudos radiológicos no Brasil, propor uma tradução para o termo e fazer uma breve revisão sobre o tema. Materiais e Métodos: Foi enviada uma pesquisa, por meio de mensagem eletrônica, para diversos radiologistas de todo o Brasil, questionando sobre a familiarização com o termo, qual tradução em português utilizam e se usam os critérios propostos pela diretriz da Sociedade Fleischner. Resultados: Foram recebidas 163 respostas de todas as regiões do Brasil e a grande maioria dos radiologistas respondeu estar familiarizado com o termo interstitial lung abnormalities (88%), mas houve grande variação em relação ao termo utilizado como tradução para o português. Conclusão: Sugerimos a padronização do termo “anormalidades pulmonares intersticiais”, a fim de uniformizar os relatórios radiológicos e difundir esta entidade no País.

    Abstract in English:

    Abstract Objective: To conduct a survey on the use of the term “interstitial lung abnormalities” in radiology reports in Brazil, propose an appropriate Portuguese-language translation for the term, and provide a brief review of the literature on the topic. Materials and Methods: A survey was sent via electronic message to various radiologists in Brazil, asking about their familiarity with the term, which translation of the term they use in Portuguese, and whether they use the criteria proposed by the Fleischner Society. Results: A total of 163 responses were received, from all regions of Brazil. Although the vast majority (88%) of the respondents stated that they were familiar with the term “interstitial lung abnormalities”, there was considerable variation regarding the equivalent term they used in Portuguese. Conclusion: We suggest that the term “anormalidades pulmonares intersticiais” be used in order to standardize radiology reports and disseminate knowledge of these findings in Brazil.
  • Computed tomography and magnetic resonance imaging in Brazil: an epidemiological study on the distribution of equipment and frequency of examinations, with comparisons between the public and private sectors Original Article

    Alencar, Camila de Almeida Costa; Oliveira, Dante Claudino de; Teixeira, Aylla Batista Moreira; Lemos, Lívia Maria Goes; Quesado, Raquel Cristina Saldanha; Santos, Ionara Maria de Almeida; Lins, Carolina Freitas

    Abstract in Portuguese:

    Resumo Objetivo: Comparar informações sobre procedimentos radiológicos de alta complexidade – tomografia computadorizada (TC) e ressonância magnética (RM) –, considerando o número de aparelhos e o quantitativo de exames nas esferas pública e privada nas cinco regiões brasileiras entre 2015 e 2021. Materiais e Métodos: Trata-se de um estudo descritivo de série temporal que utilizou dados secundários do Departamento de Informática do Sistema Único de Saúde, órgão do Ministério da Saúde (MS) responsável pela coleta e armazenamento das informações relacionadas à saúde no Brasil. Analisamos os números de aparelhos e de exames de TC e RM, considerando os tipos de aparelhos e exames, instituição (pública ou privada), região brasileira e ano (2015 a 2021). Resultados: Houve aumento de aparelhos e exames de TC e RM em todas as regiões ao longo dos anos. A esfera privada apresentou maior aquisição desses aparelhos e crescimento no número de exames. O sistema público não atingiu o número de aparelhos preconizado pelo MS, enquanto o sistema privado superou a recomendação. Observou-se maior número de exames na esfera privada quando comparada à pública. Conclusão: O sistema público não atendeu aos números de aparelhos e exames realizados preconizados pelo MS, diferentemente da esfera privada, em todas as regiões no período estudado.

    Abstract in English:

    Abstract Objective: To compare information on highly complex radiological procedures—computed tomography (CT) and magnetic resonance imaging (MRI)—between the public and private health care systems, across the five regions of Brazil, in terms of the numbers of radiological devices and examinations performed, between 2015 and 2021. Materials and Methods: This was a descriptive time series analysis of secondary data in the public domain, available from the Information Technology Department of the Brazilian Unified Health Care System, an entity of the Brazilian National Ministry of Health (NMH) that is responsible for collecting and storing health-related information in Brazil. The analysis included the numbers of CT and MRI scanners; the volumes and types of examinations; the type of institution (public or private); the regions of the country; and the years (2015 to 2021). Results: Progressive increases in the numbers of CT and MRI devices, as well as in the volumes of examinations, were observed over the years in all regions of the country. The private sector showed higher rates of equipment acquisition and of growth in the number of examinations. However, the public health care system did not reach the equipment targets set by the NMH, whereas the private health care system surpassed those targets. A greater number of examinations were performed in the private sector than in the public sector. Conclusion: During the period evaluated, the public health care system did not meet the equipment or examination targets recommended by the NMH, in any of the regions of the country, unlike the private health care system, which exceeded both in all of the regions.
  • The dark side of T2: central nervous system lesions with low signal intensity on T2-weighted imaging Review Article

    Carpentieri-Primo, Pedro; Nahoum, Luiza; Almeida, Louise; Nacur, Fernando; Alves Júnior, Sérgio Ferreira; Ventura, Nina

    Abstract in Portuguese:

    Resumo A grande maioria das doenças do sistema nervoso central apresenta alto sinal em ponderações T2 na ressonância magnética. As alterações com baixo sinal são menos comuns, de forma que essa característica permite estreitar o diagnóstico diferencial. Analisamos, retrospectivamente, pacientes com imagens de ressonância magnética de crânio e/ou coluna em que este achado foi útil na investigação diagnóstica. Os pacientes foram selecionados no período entre 2015 e 2022 e todos tiveram seus diagnósticos confirmados por estudo clinicorradiológico ou por estudo histopatológico. Obtivemos imagens de 14 pacientes com as seguintes afecções: malformação arteriovenosa, cavernoma, metástase de linfoma, meduloblastoma, tumor embrionário, metástase de melanoma, cisto da bolsa de Rathke, doença de Erdheim-Chester, aspergilose, paracoccidioidomicose, tuberculose, sífilis, doença relacionada à IgG4 e metástase de tumor neuroendócrino de pulmão. Descrevemos lesões de diversas origens etiológicas que, a partir de suas características nas imagens ponderadas em T2, foi possível reduzir o quadro de diagnósticos diferenciais e chegar mais facilmente à hipótese final.

    Abstract in English:

    Abstract The majority of central nervous system diseases show high signal intensity on T2-weighted magnetic resonance imaging. Diseases of the central nervous system with low signal intensity are less common, which makes it a finding that helps narrow the differential diagnosis. This was a retrospective analysis of brain and spine magnetic resonance imaging examinations in which that finding was helpful in the diagnostic investigation. We selected the cases of patients examined between 2015 and 2022. All diagnoses were confirmed on the basis of the clinical-radiological correlation or the histopathological findings. We obtained images of 14 patients with the following central nervous system diseases: arteriovenous malformation; cavernous malformation; metastasis from lymphoma; medulloblastoma; embryonal tumor; metastasis from melanoma; Rathke’s cleft cyst; Erdheim-Chester disease; aspergillosis; paracoccidioidomycosis; tuberculosis; syphilis; immunoglobulin G4-related disease; and metastasis from a pulmonary neuroendocrine tumor. We described lesions of different etiologies in which the T2-weighted imaging profile helped narrow the differential diagnosis and facilitated the definitive diagnosis.
  • Decoding dose descriptors for computed tomography News In Radiology

    Kalra, Mannudeep K.; Karout, Lina; Kiipper, Felipe de Moura; Bernardo, Mônica Oliveira
  • The challenges of balancing clinical and research responsibilities Letter To The Editor

    Arkoudis, Nikolaos-Achilleas; Efthymiou, Evgenia; Moschovaki-Zeiger, Ornella; Koutserimpas, Christos
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem Av. Paulista, 37 - 7º andar - conjunto 71, 01311-902 - São Paulo - SP, Tel.: +55 11 3372-4541, Fax: 3285-1690, Fax: +55 11 3285-1690 - São Paulo - SP - Brazil
E-mail: radiologiabrasileira@cbr.org.br